3COM CORPORATION AUTO DIAL S-100 Card Type Modem (asynchronous) Chip Set U.S. Robotics Maximum Data Rate 1200bps Data Bus External Data Modulation Protocol Bell 103/212A 54168 CONNECTIONS Function Label Function Label Line out CN1 DC power CN4 Line in CN2 Power switch SW1 RS-232/422 CN3 USER CONFIGURABLE SETTINGS Setting Label Position Factory configured J1 Unidentified 10-bit character transmission J2 Unidentified 11-bit character transmission J2 Unidentified Equalize for dial-up phone lines J5 Unidentified Equalize for dedicated phone lines J5 Unidentified ADDRESS SELECTION Setting S6/A S6/B S6/C S6/D J6 00/01 Off Off Off Off Off 0E/0F Off Off Off Off On 10/11 Off Off Off On Off 1E/1F Off Off Off On On 20/21 Off Off On Off Off 2E/2F Off Off On Off On 30/31 Off Off On On Off 3E/3F Off Off On On On 40/41 Off On Off Off Off 4E/4F Off On Off Off On 50/51 Off On Off On Off 5E/5F Off On Off On On 60/61 Off On On Off Off 6E/6F Off On On Off On 70/71 Off On On On Off 7E/7F Off On On On On 80/81 On Off Off Off Off 8E/8F On Off Off Off On 90/91 On Off Off On Off 9E/9F On Off Off On On A0/A1 On Off On Off Off AE/AF On Off On Off On B0/B1 On Off On On Off BE/BF On Off On On On C0/C1 On On Off Off Off CE/CF On On Off Off On D0/D1 On On Off On Off DE/DF On On Off On On E0/E1 On On On Off Off EE/EF On On On Off On F0/F1 On On On On Off FE/FF On On On On On Note: J6 ‘Off’ position in table corresponds to ‘Up’ position on board. J6 ‘On’ position corresponds to ‘Down’ position. MISCELLANEOUS TECHNICAL NOTES Note: Diagram not available. Proprietary AT Command Set See document V2252 for a full command summary.